Main features steel roof design example.
Steel roof deck design example.
Steel roof deck constructions.
Our lightweight composite and non composite steel deck profiles have depths that range from 7 8 to 71 2.
The roof deck is a wr wide rib type panel with a panel width of 36.
Roof diaphragms may be assembled from a wide variety of panel profiles including narrow rib nr intermediate rib ir and wide rib wr.
31 design manual for composite decks form decks.
The roof deck is supported by joists that are thick and spaced at 5 ft.
Design a roof deck for a length of l 500 ft.
And a width b 300 ft.
Vulcraft roof deck design tools 2018 ibc deck diaphragm calculate your unfilled deck diaphragm shear and stiffness for your exact condition based on the american iron and steel institute aisi s310 16.
The second edition of the sdi roof deck design manual rddm2 2020 by steel deck institute includes 15 design examples and 40 ksi load tables including new ones for concentrated and moving loads.
Download the first edition of our steel deck on cold formed steel framing design manual sdcfsfdm or visit our order page to purchase a printed and bound copy.
Roofdeck is a spreadsheet program written in ms excel for the purpose of analysis and design of roofs with steel deck.
Sdi manufacturers can furnish fire ratings load test results and other perform ance test reports for their own products.
Using 5 8 inch puddle welds for attaching deck to supports and 10 sidelap screws we find the nominal shear strength in the table for 0 0295 inch thick wr deck is 0 740 klf using a 36 4 12 inch o c support fastener.
Panel lengths range from 3 6 to 45.
Specifically roof decks subjected to gravity loading dead live or snow and wind uplift loading can be analyzed using either asd or lrfd methods.
First off the steel roof design example is an extremely basic direct and utilitarian design every single current trademark.
Our lightweight steel deck profiles have depths that range from 13 8 to 71 2.
Asc steel deck offers a robust selection of products.
Panel lengths range from 5 feet to 45 feet.
Design the diaphragm for wind loading using allowable stress design method.
Using the steel deck institute sdi diaphragm design manual third edition we can determine the required deck fastening.
Now let s work on an example.
The steel roof design example can go up against different style that when nitty gritty right can ooze a cutting edge feel.
Steel deck diaphragms.
Steel deck panels are supplied with both galvanized and painted finishes to meet an array of project finish requirements.